Storing Character data in case of Outputting via PLC
communication
When "Protocol" has been set to "PLC Communication", 2 characters are stored in each data register starting
from the lower 8 bits of the specified data register.
Example)
Condition: No. of Output = 5
Characters to be output: HELLO
Start Register: 100
Output Result:
Register No.
100
101
102
Setting Number of Lines
Set the number of lines of character strings to be recognized.
1.
Select "Number of Lines".
2.
Select "One" when the recognized character
string is one line, and select "Two or more"
when the strings are two lines or more.
Default: "Two or more"
If selecting "Two or more" when a single line string is recognized of which characters are misaligned, the
order of recognized characters might be changed.
Higher 8 bits
Lower 8 bits
E
L
(Space)
H
L
O