4. FUNCTION SETTINGS
Initial values for each application
No.
KE-430F-03
151
152
1200
153
2500
154
3200
155
3200
156
3200
157
3200
158
3200
159
2400
No.
Setting range
161
ON/OFF
162
ON/OFF
430F: 1200 − 3200
(sti/min)
163
438F: 1200 − 2700
(sti/min)
164
ON/OFF
-20 − 20
165
(degrees)
10 − 500
166
(ms)
167
ON/OFF
OFF, 1 − 120
168
(seconds)
30 − 89
169
(degrees)
430F: 0 − 2800
(sti/min)
170
438F: 0 − 2300
(sti/min)
171
ON/OFF
12
KE-430F-05
800
1500
2000
2500
3200
3200
3200
3200
3200
2700
Initial
Setting units
value
OFF
OFF
3200
100
2700
OFF
0
150
OFF
OFF
45
0
100
ON
KE-430F-0K
400
800
1200
2500
3200
3200
3200
3200
2400
Effective hammer operation when needle does not pierce
-
ON: Enabled
OFF: Disabled
Regulation of sewing speed changes due to sewing pitch
changes
ON: Restricted (Speed is fixed at the minimum sewing speed
for the maximum pitch of the sewing data.)
-
* Set to ON if there may be a problem with sewing
speed changes as a result of pitch changes.
OFF: Not restricted (Sewing speed varies depending on
sewing pitch of the sewing data.)
Sewing speed limit value
* When setting the sewing speed, the speed will be limited by
this value.
Thread trimming operation prevention
ON: All thread trimming operations are disabled.
-
OFF: Thread trimming is carried out in accordance with the
sewing data.
Stop position at highest needle position stop
−: Becomes higher
1
+: Becomes lower
Delay time until reverse operation starts during highest needle
10
position stop operation
Servo lock operation
-
ON: Used
OFF: Not used
Servo lock timer setting
* Enabled when No. 167 is set to "ON".
1
OFF: No timer operation
1 to 120: Timer operation (1 to 120 secs.)
Servo lock release rotation angle
1
* Enabled when No. 167 is set to "ON".
Lowers the allowable speed for the sewing pitch by the
amount set.
However, the minimum allowable speed value is 400 sti/min.
Automatic needle lifter operation
ON: If the needle bar is not at the needle up stop position
during work clamp/button clamp home position detection,
it moves automatically to the needle up stop position.
-
OFF: An "UP" error is displayed without the needle bar moving
automatically.
(No. 655 can also be used to ignore this sensor.)
KE-430F, BE-438F
KE-430F-0F
BE-438F
800
400
1200
400
2500
600
3200
900
3200
2700
3200
2700
3200
2700
3200
2700
2400
2700
Setting details