Measurement (M5)
Setting zeros, workpiece measuring and tool measuring
Error messages
If the client does not log on, group error number 0xD003 is always generated. If a logon
takes place through DIAGN:errCodeSetNrGent or DIAGN:errCodeSetNrPi, then PI_SETUDT
provides the error code corresponding to the following syntax:
EX_ERR_PI_REJ_<Return value>, e.g.: EX_ERR_PI_REJ_ MEASNOTYPE
The following return values are output via the pre-defined MEASURE() function:
Table 8- 8
No.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Tool measurement error
In the case of error code MEAS_TOOL_ERROR or EX_ERR_PI_REJ_MEASTOOLERROR,
the system stores a more detailed specification of the error with the following values in
output variable $AC_MEAS_TOOL_LENGTH:
Table 8- 9
No.
1
2
3
4
5
6
7
638
Predefined error messages
Return values
MEAS_OK
MEAS_NO_TYPE
MEAS_TOOL_ERROR
MEAS_NO_POINT1
MEAS_NO_POINT2
MEAS_NO_POINT3
MEAS_NO_POINT4
MEAS_NO_SPECPOINT
MEAS_NO_DIR
MEAS_EQUAL_POINTS
MEAS_WRONG_ALPHA
MEAS_WRONG_PHI
MEAS_WRONG_DIR
MEAS_NO_CROSSING
MEAS_NO_PLANE
MEAS_WRONG_FRAME
MEAS_NO_MEMORY
MEAS_INTERNAL_ERROR
Predefined error messages for MEAS_TOOL_ERROR
Return values
TOOL_NO_BLOCK
TOOL_WRONG_T_NUMBER
TOOL_WRONG_D_NUMBER
TOOL_EVAL_WRONG_TYPE
TOOL_NO_TOOLCORR_BODY
TOOL_DATA_READ_ERROR
TOOL_NO_TOOL_WITH_TRAFO
Description
Correct calculation
Type not specified
Error determining the tool
Measuring point 1 does not exist
Measuring point 2 does not exist
Measuring point 3 does not exist
Measuring point 4 does not exist
No reference point available
No approach direction
Measuring points are identical
Alpha α is wrong
Phi ϕ is wrong
Wrong approach direction
Lines do not intersect
Planes do not exist
No frame or incorrect frame selected
Insufficient memory available
Internal error
Description
No block available for the tool calculation
Wrong T number
Wrong D number
The tool does not exist
Memory problem
Error reading the tool data
No tool is selected with an active transformation