Supplementary Software Conditions - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Parallel STEP7/AS300 application
Installation in parallel with the STEP7/AS300 SW can give rise to problems. It may be
necessary to reconfigure the drives and restart the system.
3.2.3

Supplementary software conditions

● Function keys
● Monochrome screen
● User-friendly parameterization
Extended Functions
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
– "netnames.ini" file
The following lines in the file must be changed:
# bus = opi must be replaced by = mpi
# nck_address = 13 must be replaced by = 3 (if PLC ≥ software version 3.2)
= 13 (if PLC < software version 3.2)
# plc_address = 13 must be replaced by 2
The function keys must not be actuated in any of the displays until the display has fully
built up.
When a monochrome screen is used, the colors used by the MMC must be adapted
accordingly. For this purpose, select the color scheme "Monochrome" or "Mono positive"
in display "Commissioning\MMC\Color setting".
The display "Commissioning\MMC\OPI parameters" can now be called up even if there is
no link to the NC kernel. This means that the OPI parameters for baud rate and network
address can be set easily.
Operation via PG/PC (B4)
Software installation
275