Digital and Analog NCK I/Os (A4)
NCK I/O via PLC
Examples
Connect:
MD10361 $MN_FASTIO_DIG_SHORT_CIRCUIT = '04010302H'
Output 4, byte 1, connect to
Input 3, byte 2
AND operation:
MD10361 $MN_FASTIO_DIG_SHORT_CIRCUIT = '0705A201H'
Output 7, byte 5 AND operation with
Input 2, byte 1
OR operation:
MD10361 $MN_FASTIO_DIG_SHORT_CIRCUIT = '0103B502H'
Output 1, byte 3 OR operation with
Input 5, byte 2
1.2.4
NCK analog inputs/outputs
1.2.4.1
NCK analog inputs
Amount
General machine data is used to define available analog NCK inputs:
MD10300 $MN_FASTIO_ANA_NUM_INPUTS(Number of analog NCK inputs)
Function
The value of the analog NCK input [n] can be accessed directly in the part program using
system variable $A_INA[n].
The analog value at the hardware input can also be influenced by the PLC user program
(see fig.).
40
Function Manual, 03/2009, 6FC5397-1BP10-4BA0
Extended Functions