Power Drawer - Hitachi EC701HP Operation Manual

700w uhf 8vsb-atsc transmitter
Table of Contents

Advertisement

Section 3 - Installation (ATSC EC701HP Transmitter)
3.5.2

Power Drawer

INDICATOR LEDS
USB INTERFACE
Changing Functions of the LED's of the GV 40001 front panel
1) Status dos LEDs
Green light indicates OK
Orange light indicates that ocurred a failure
Flashing Red light indicates that is ocurring a failure
LED's Functions - MOD GV 40001 HP.PA
LED
PWR
This LED lights only GREEN indicating that is POWERED ON.
SHDN
Power Supply Shutdown
FWD
Over Forward Power
RFD
Re?ected Power
PA Failure, High Current on PA, Low Current on PA, Current UNBAL on PA, Low Gain on PA, High Temperature on PA
PA
Com munication Failure on PA.
High Current on Driver, Low Current on Driver, Low Current on Pre Driver, High Current on Pre Driver, Low Gain on
Driver, High Temperature on Driver, Low Voltage on Driver, Communication Failure on Driver, High Input Signal, High
DRV
Driver Output Level.
Low AC Line Voltage, High AC Line Voltage, Low PSU Voltage, High PSU Voltage, High PSU Current, High PFC
PSU
Temperature, High DC/DC Temperature, PSU Communication Failure.
Low Speed on FAN1, Low Speed on FAN2, Low Speed on FAN3, Low Speed on PSU FAN, FAN1 Failure, FAN2 Failure,
FAN /
FAN3 Failure, PSU FAN Failure,
TEMP
Manual Rev. 0.0 - March 2018
Front View of Power Drawer - Module MOD GV 40001 / 40087
High power drawer input air temperature (greater than 35ºC).
Figure 3-9
ALARM
ON/OFF SWITCH
3-14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec702hpEc703hpEc704hpEc706hpEc708hpEc712hp

Table of Contents