On Site Physical Assembly; Assembly Instructions - Hitachi EC701HP Operation Manual

700w uhf 8vsb-atsc transmitter
Table of Contents

Advertisement

Section 3 - Installation (ATSC EC701HP Transmitter)
3.7

ON SITE PHYSICAL ASSEMBLY

NOTE: trained personnel ONLY should conduct the on-site physical assembly.
The following precautions should be taken when positioning the transmitter at the installation
site:
1) The air intake (front) and air outlet (back) should be completely clear.
2) The transmitter rack must be positioned in such a way so as to ensure easy access
from any side. The gap between the transmitter and the shelter walls must be minimum 1.0
meter.
3) In case of installation on a site that contains other transmitters connected, do not position
the transmitter in a location that can receive hot air from other transmitters.
3.7.1
1- Unpacking the transmitter, power drawer and filter.
2- Position the rack where the equipment is installed in compliance with the following issues:
Antenna cable
AC Power Supply
RF Cable
Transport Stream (ASI) cables
Grounding point
Visual Inspection:
a. Remove the lateral and rear panel of the transmitter and proceed to a visual inspection
searching for any alteration that may have happened during the transportation of the equipment.
b. Pay special attention on the RF and signal cable connectors, ie. loose screws.
c. Check unit switches, make sure they are in the "ON" position.
Grounding:
For personal and equipment safety reasons, connect the ground of the of the transmitter room
to the ground of equipment before proceeding to the next steps.
Manual Rev. 0.0 - March 2018

Assembly Instructions

ATTENTION
Figure: 3-15
AC Grounding
Site Grounding
3-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ec702hpEc703hpEc704hpEc706hpEc708hpEc712hp

Table of Contents