HUAWEI TP3106&TP3118&TP3118S
Commissioning Guide
Parameter
Video MODE
Notes:
l
l
Procedure
Step 1 Telnet to the telepresence codecs.
To telnet to the telepresence codec whose IP address is 10.11.250.61, do the following: Choose
Start > Run. In the Run dialog box, enter telnet 10.11.250.61, and press Enter. On the displayed
window, enter debug for the login name and Change_Me for the password.
The window shown in the following figure is displayed.
Step 2 Query the camera's current settings.
Run camctrl camzoomsetting inquire on.
Issue 01 (2015-02-12)
Shutter speed, Iris VAL, and Gain VAL are available to be set only when AE MODE is
set to manual.
Do not set Aperture VAL to a value smaller than 8, because this will decrease video clarity.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Value
Sets the video resolution
(0-7).
l 0: 1080p/30 Hz
l 1: 1080p/25 Hz
l 2: 720p/60 Hz
l 3: 720p/50 Hz
l 4: 1080i/50 Hz
l 5: 1080i/60 Hz
l 6: 1080p/50 Hz
l 7: 1080p/60 Hz
7 Appendix
Command
videomode
148