Chapter 2 Useful Features
5.2

Menu Tree

: Selection and execution parameter
: Can be set or modified after a Virtual Drive is created
Menu
Configure
Easy Configuration
New Configuration
View/Add Configuration
Clear Configuration
Select Boot Drive
Initialize
Objects
Adapter
Sel. Adapter
Rebuild Rate
Chk Const Rate
FGI Rate
BGI Rate
Disk WC
Read Ahead
Bios State
Cont on Error
Fast Init
Auto Rebuild
Auto Resume
Disk Coercion
Factory Default
Virtual Drive
Virtual Drives
Initialize
Check Consistency
View/Update Parameters
• RAID
• SIZE
• Stripe SIZE
• #Stripes
• State
• Spans
• Disk WC
• Read Ahead
: Setting parameter
Specify configuration settings
Set a configuration using fixed values
Set a new configuration
Add or view a configuration
Clear the configuration data
Select a Virtual Drive to be booted
Initialize the Virtual Drive
Set up various objects
Set up the RAID Controller
Select an adapter
30
30
30
30
Off
On
Enable
Yes
Enable
On
Enable
1 GB
Reset to the default values
Operate a Virtual Drive
Select a Virtual Drive (when multiple Virtual Drives exist)
Initialize the Virtual Drive
Check Virtual Drive consistency
View the Virtual Drive information
View the RAID level
View the Virtual Drive capacity
View the stripe size
View the number of Hard Disk Drives in the Virtual Drive
View the Virtual Drive status
View the span setting
View the write cache setting
View the read ahead setting
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
5. RAID System Configuration
•: Data display
Description
(1/2)
103