NEC Express 5800 Series Maintenance Manual page 142

Express server
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
BMC Message on Lower LCD Line
DIMM Area Temperature Upper
Non-Critical
DIMM Area Temperature Lower
Critical
DIMM Area Temperature Upper
Critical
Processor Thermal Control
Upper Non-Critical
Processor Thermal Control
Upper Critical
DUMP Request !
OS shutdown Alm
Power Supply1 Failure
detected
Power Supply2 Failure
detected
Power Supply1 AC Lost
Power Supply2 AC Lost
Processor Missing
Processor Thermal Trip
DIMM1 Uncorrectable Error
DIMM2 Uncorrectable Error
DIMM3 Uncorrectable Error
DIMM4 Uncorrectable Error
Processor Internal Error
Sensor Failure Detected.
SMI timeout
IPMI Watchdog timer timeout
(Power off)
142
Description
A temperature abnormality was
detected.
The dump button was pressed.
An OS stop error occurred.
A power supply unit abnormality
occurred.
AC input of a power supply unit
was abnormality.
No CPU is installed.
The power was forcibly turned off
due to a CPU temperature
abnormality.
An unrecoverable error occurred
for DIMM1.
An unrecoverable error occurred
for DIMM2.
An unrecoverable error occurred
for DIMM3.
An uncorrectable error occurred
for DIMM4.
An internal CPU error (IERR)
occurred.
Abnormality in a sensor was
detected.
A timeout occurred while
servicing system management
interrupts.
A watchdog timer timeout
occurred.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
1. POST Error Message
Action
A cooling fan has a failure or is clogged
by dusts. Contact your sales
representative.
Wait until collecting the memory dump
is complete.
Write down the displayed message,
wait until collecting the memory dump
is complete, and then contact your
sales representative.
Make sure that the power cord is
plugged in. If this does not resolve the
problem, contact your sales
representative.
Contact your sales representative.
Contact your sales representative.
(2/4)