Error Message
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC
FRU corrupted.
BMC SDR Repository empty. BMC device (chip) error
C10E
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository
failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
BMC Fatal hardware error. BMC error
C114
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition
is invalid.
C11D
BMC is in Forced Boot
Mode.
C11E
Communication with BMC
was failed in previous
boot.
C200
The error occurred during
memory configuration
check.
C201
Memory Configuration
change is detected.
C202
The error occurred during
CPU configuration check.
C203
CPU Configuration change
is detected.
C300
Out-of-band setup
configuration failure
C301
SDR mismatch error
C322
No information for system
power consumption check
C501
Intel(R) Node Manager is
in Recovery Mode
Description
BMC device (chip) error
Chassis information is incorrect.
SMC (Satellite Management
Controller) failure
Failure of the SROM for storing
chassis information
Failure of the SROM for storing
sensor data record information
BMC device (chip) failure
BMC RAM error
BMC Mezzanine card is not
mounted.
BMC Mezzanine partition is
invalid.
The Forced Boot Mode of BMC
was detected.
Communication with BMC was
failed in previous boot.
The memory information could
not be obtained.
The memory configuration has
changed since the previous
startup.
The CPU information could not
be obtained.
The CPU configuration has
changed since the previous
startup.
Invalid access to BMC
Mezzanine card
Inconsistency in the hardware
information of the sensor data
record was detected
The information for system
power consumption was not
detected.
The Recovery Mode of Intel(R)
Node Manager was detected.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
1. POST Error Message
Action
Turn off the power, disconnect the
server from the outlet, wait for at least
30 seconds, and restart the server. If
the error occurs again, contact your
sales representative.
Check the jumper switch on the
motherboard. Unplug the power
cable, wait for at least 30 seconds,
and then restart the server. If the
error is detected again, contact your
sales representative.
Contact your sales representative.
Turn off the power and restart the
server. If the error is detected again,
contact your sales representative.
When Check previous system
Config is enabled in server of the
BIOS settings, this message appears
if the configuration was changed
since the previous startup. If this
message appears even when no
configuration change has been made,
contact your sales representative.
Turn off the power and restart the
server. If the error is detected again,
contact your sales representative.
When Check previous system
Config is enabled in server of the
BIOS settings, this message appears
if the configuration was changed
since the previous startup. If this
message appears even when no
configuration change has been made,
contact your sales representative
Contact your sales representative.
Contact your sales representative.
Check the jumper switch on the
motherboard. Unplug the power
cable, wait for at least 30 seconds,
and then restart the server. If the
same error is detected again, contact
your sales representative.