Chapter 3 Appendix
(1) Error messages
Error Message
System variable is
8000
corrupted.
8002
Check date and time
settings
8006
System configuration data
cleared by Jumper.
8007
SETUP Menu Password
cleared by Jumper.
8020
BIOS update error.
8021
Recovery jumper is set,
but recovery images is not
found.
8800
DXE_NB_ERROR
8801
DXE_NO_CON_IN
8802
DXE_NO_CON_OUT
9000
Unsupported CPU
detected
9E80
Forced to use CPU with
error.
AB00
Memory not detected
AE01
DIMM1 has been disabled. A memory error occurred.
AE02
DIMM2 has been disabled. A memory error occurred.
DIMM3 has been disabled. A memory error occurred.
AE03
AE04
DIMM4 has been disabled. A memory error occurred.
AE81
DIMM1 with error is
enabled.
AE82
DIMM2 with error is
enabled.
B000
Expansion ROM not
initialized
B001
Expansion ROM not
initialized - PCI Slot 1
(Express5800/T110f-S,
T110f-E)
B002
Expansion ROM not
initialized - PCI Slot 2
(Express5800/T110f-S,
T110f-E)
B003
Expansion ROM not
initialized - PCI Slot 3
(Express5800/T110f-S,
T110f-E)
134
Description
BIOS settings are invalid.
The real-time clock is incorrect.
The setup utility settings were
cleared by the jumper.
The setup utility password was
cleared by the jumper.
BIOS update failed.
The recovery jumper is set but
the BIOS recovery failed.
An error was detected during
initialization of the chipset
An error was detected during
initialization of the console.
An unsupported CPU was
detected.
A CPU error occurred.
No valid memory is installed.
DIMM1 has been disabled.
DIMM2 has been disabled.
DIMM3 has been disabled.
DIMM4 has been disabled.
An error in DIMM1 occurred.
The DIMM1 was forcibly enables
because all memory is currently
disabled.
An error in DIMM2 occurred.
The DIMM2 was forcibly enables
because all memory is currently
disabled.
There is no memory for
expanding option ROM.
Option ROM expansion in PCI
slot 1 failed.
Option ROM expansion in PCI
slot 2 failed.
Option ROM expansion in PCI
slot 3 failed.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
1. POST Error Message
Action
Run the setup utility, and then
execute Load Setup Defaults and
specify the necessary settings. If the
same error continues to occur,
contact your sales representative.
Run the setup utility, and then specify
the correct date and time. If the same
error continues to occur, contact your
sales representative.
See Chapter 1 (7. Resetting and
Clearing the Server).
Try BIOS update again. If it fails
again, contact your sales
representative.
Contact your sales representative.
Check if the memory modules are
properly installed. If the same error is
displayed consecutively, contact your
sales representative.
Contact your sales representative.
If the PCI board does not connect to a
bootable device, disable the Option
ROM Scan for that board.