Troubleshooting; Problem Of Powering On - NEC Express 5800 Series Maintenance Manual

Express server
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

Chapter 1 Maintenance
5.

Troubleshooting

If the server does not work correctly, check it according to the contents of the following checklist before sending
it for repair.
If the server still does not work correctly, write down the error messages displayed on the screen and then
contact your sales representative.
5.1

Problem of Powering on

[?]
When the power cable is connected, the POWER LED turns on.
POWER LED lights amber during initialization of the server after connecting the power cord.
POWER LED turns off when initialization finishes.
[?]
Fail to power on the server
Is the server properly supplied with power?
Check if the power cord connects to the power outlet (or UPS) that meets the power specifications for
the server.
Use the power cord that comes with the server. Additionally, check the power cord for broken shield or
bent plugs.
Make sure the power breaker for the connected power outlet is on.
If the power cord is plugged to a UPS, make sure the UPS is powered and it outputs power. Refer to the
manual that comes with the UPS for details.
Power supply to the server may be linked with UPS using the BIOS Setup utility.
Did you press POWER Switch?
Wait until POWER LED is unlit if POWER LED lights amber, and then press the switch on the front of
the server to turn on the power.
Is Standby Power Save set to Enabled in the BIOS setup?
When Standby Power Save is enabled, remote power on is not allowed, and you can power on the
server only by using POWER Switch on the server. If you change the AC Link setting while Standby
Power Save is enabled, you need to press the switch twice to start up the server.
26
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide