NEC Express 5800 Series Maintenance Manual page 136

Express server
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
B23A
PCI Slot 1A - PCIe Link
Width Error
(Express5800/R110f-1E)
B23B
PCI Slot 1B - PCIe Link
Width Error
(Express5800/R110f-1E)
B261
Onboard LAN 1 - PCIe Link
Speed Error
B262
Onboard LAN 2 - PCIe Link
Speed Error
B271
PCI Slot 1 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
B272
PCI Slot 2 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
B273
PCI Slot 3 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
B274
PCI Slot 4 - PCIe Link
Speed Error
(Express5800/T110f-S,
T110f-E)
B27A
PCI Slot 1A - PCIe Link
Speed Error
(Express5800/R110f-1E)
B27B
PCI Slot 1B - PCIe Link
Speed Error
(Express5800/R110f-1E)
C010
The error occurred during
temperature sensor
reading
C011
System Temperature out of
the range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C103
BMC core hardware
failure.
C104
BMC IBF or OBF check
failed.
C105
BMC SEL area full.
136
Description
A PCIe bus link width error was
detected in PCI slot 1A.
A PCIe bus link width error was
detected in PCI slot 1B.
A PCIe bus link speed error was
detected on the onboard LAN1
port.
A PCIe bus link speed error was
detected on the onboard LAN2
port.
A PCIe bus link speed error was
detected in PCI slot 1.
A PCIe bus link speed error was
detected in PCI slot 2.
A PCIe bus link speed error was
detected in PCI slot 3.
A PCIe bus link speed error was
detected in PCI slot 4.
A PCIe bus link speed error was
detected in PCI slot 1A.
A PCIe bus link speed error was
detected in PCI slot 1B.
An error occurred while reading
the temperature sensor.
A temperature abnormality was
detected.
An error occurred while reading
the voltage sensor.
A system voltage abnormality
was detected.
SROM data reading error
An error occurred in the 1st SM
Bus.
An error occurred in the 2nd SM
Bus.
An error occurred in the 3rd SM
Bus.
An error occurred in the 4th SM
Bus.
An error occurred in the 5th SM
Bus.
An error occurred in for the 6th
SM Bus.
An error occurred in the 7th SM
Bus.
An error occurred in the 8th SM
Bus.
BMC device (chip) error
Accessing the BMC address
failed.
No memory to write the system
event log.
Express5800/T110f-S, R110f-1E, T110f-E Maintenance Guide
1. POST Error Message
Action
Contact your sales representative.
Contact your sales representative.
A cooling fan has a failure or is
clogged by dusts. Contact your sales
representative.
Contact your sales representative.
Turn off the power, disconnect the
server from the outlet, wait for at least
30 seconds, and restart the server. If
the error occurs again, contact your
sales representative.
Run the offline tools by pressing <F4>
key and delete the event logs.
(3/4)