Panasonic AV-HS6000 Series Operation Manual page 142

2me live switcher
Hide thumbs Also See for AV-HS6000 Series:
Table of Contents

Advertisement

Reference
(System standard)
1H output
(+1H)
Shortest
output
(+0.5H)
0H output
(1F delay for Reference and in-phase
output)
Frame synchronizer range
Within a max. of 1 frame
Phases and delay amount of input/output signals when HD format is used
Frame synchronizer
[FS]:
[Off], [Strict], [Acceptable]
Input signal
[Mode]:
[Normal], [U/C], [Dot by
Dot]*
* Not selectable when the system format is 720p.
f For details on the frame synchronizer, refer to "Setting the frame synchronizer" (page 119).
f For details on the down-converter, refer to "Setting the down-converter" (page 125).
Chapter 8 System Menu — System settings
Line synchronizer range
Approx. −0.3H to +0.7H
Approx. 0.3H
Line synchronizer range
Approx. −0.8H to
+0.2H
Approx. 0.2H
Longest output
(+1.5H)
Approx. 0.2H
Approx. 0.3H
Internally fixed delay
Output phase variable range
H phase ([−0.50H] to [0.49H])
V phase ([−100H] to [100H])
Reference
(Reference phase)
Image effects
– 142 –
Approx. 0.3H
Output phase variable range
H phase ([−0.50H] to [0.49H])
V phase ([−100H] to [100H])
Internally fixed delay
Output phase variable range
+0.5H
H phase ([−0.50H] to [0.49H])
V phase ([−100H] to [100H])
Line synchronizer range
Approx. +0.2H to +1.2H
Output phase variable range
+0.5H
H phase ([−0.50H] to [0.49H])
V phase ([−100H] to [100H])
Down-converter
[Delay]
[90H] ([75H]), [1F]
Internally fixed
delay
Internally
fixed delay
Output signal 1
Output signal 2

Advertisement