3
Select an item in [Pattern] in the [H Modulation]/[V Modulation] column.
[Sine]
[Delta]
Setting the transition MID Position
Adjusts the position and size of the pattern waveform when the transition amount is in the range of 40% to 60% (mid position).
f Enabled when the following pattern waveforms are selected.
- SQ: 51, 52, 53, 54
1
Select the <ME1>/<ME2> button → [BKGD] → [Modify] tab.
2
Set [X] and [Y] in the [MID Position] column.
Sets the position of the pattern waveform.
f SQ: 51 will place two sub-screens symmetrical to the Y axis.
f SQ: 52 will place two sub-screens symmetrical to the X axis.
f SQ: 53 will place two sub-screens symmetrical to the center point.
3
Set [Size] in the [MID Position] column.
Sets the size of the pattern waveform.
Setting the free pattern
Selecting the following pattern waveform allows to arbitrarily change some parameters such as the wipe shape, and position and size of the image in
PGM bus or PST bus.
f WIPE: 24 (Free Wipe)
Combines the images in the PGM bus and the PST bus with the window wipe.
f 3D: 113 (Free S-DVE)
Combines the images in the PGM bus and the PST bus using 1ch of DVE.
f 3D: 114 (Free D-DVE)
Combines the images in the PGM bus and the PST bus using 2ch of DVE.
The transition amount by the <AUTO> button or the fader lever is disabled when these waveforms are selected and the <WIPE> button is pressed.
1
Press the <WIPE> button.
2
Select the <ME1>/<ME2> button → [BKGD] → [BKGD Pattern] tab.
3
Set an item in [Pattern] of the [BKGD Pattern] column.
f Select one of WIPE: 24, 3D: 113, or 3D: 114.
4
Operate the fader lever.
f Set to a position other than the end point.
5
Select the <ME1>/<ME2> button → [BKGD] → [Free PATT] tab.
f Set the parameter in item of each column.
r Parameters that can be adjusted in each pattern
CH1 Reset, CH2 Reset
CH1 to CH2, CH2 to CH1
Prio INV
Position X, Y, Size
2nd Position X, Y, Size
Rotation X, Y, Z
2nd Rotation X, Y, Z
Trim Left, Top, Right, Bottom
2nd Trim Left, Top, Right, Bottom
r Relationship between the wipe direction <N>, <R> and PGM bus, PGM bus
Relationship between the wipe direction <N>, <R> and PGM bus, PGM bus is as follows.
Free Wipe
Chapter 5 Basic Operations — Wipe
Selects sine waves.
Selects delta wave.
Free Wipe
CH1 only
l
Z only
<N>
PGM
PST
Free S‑DVE
Free D‑DVE
CH1 only
l
l
l
l
l
l
l
l
l
l
l
l
– 59 –
Description
Initializes the parameter
Copies the parameter
Changing the CH1, CH2 priority
Position and size of CH1
Position and size of CH2
Rotation of CH1
Rotation of CH2
Trimming of CH1
Trimming of CH2
<R>
PST
PGM