2.6.6 Fitting the connector

General
This section describes how to manufacture a cable for connecting the mains power
to the controller.
Specifications
The following describes the cable and fuse requirements for the mains power
connection to the IRC5 Compact controller.
Component
Cable type
Cable area
Fuse
Included parts
The following parts are included in the delivery.
Part
Hood
Female insert
Cable gland
Procedure
Use the following procedure to fit the connectors.
1
2
Product manual - IRC5 Compact
3HAC047138-001 Revision: M
Description
Flexible oil resistant rubber
3 x 2.5 mm
Delay action fuse 16A
Recommended supplier
Harting, 19 20 003 1640
Harting, 09 12 005 2733
Harting, 19 00 000 5184
Action
Select a suitable single phase cable and earth cable,
and cut it to desired length.
Fit the cable through the cable gland and hood.
© Copyright 2009-2020 ABB. All rights reserved.
2 Installation and commissioning
2.6.6 Fitting the connector
2
Order number
3HAC051426-001
3HAC037697-001
3HAC034913-001
Note/illustration
See previous specifications.
xx0900000365
Quantity
1
1
1
A: hood
B: female insert
C: cable gland
Continues on next page