2.5.8. Fitting the connector

General
This section describes how to manufacture a cable for connecting the mains power to the
Drive Module.
Specifications
The following describes the cable and fuse requirements for the mains power connection to
the Drive Module.
Component
Cable type
Cable area
Fuse
Included parts
The following parts are included in the delivery.
Part
Female contact
Contact housing
Brass cable clamp with gasket
Procedure
Use the following procedure to fit the connectors.
3HAC021313-001 Revision: P
Description
Flexible oil resistant rubber
4 x 6mm2
Delay action fuse 25A
Action
1. Select a suitable three phase + earth cable and cut
it to desired length.
2. Make sure all parts required are available.
2 Installation and Commissioning, IRC5