4 Repair activities, controller IRC5
4.21. Replacement of Remote Service box
Continued
Removal
Use this procedure to remove the Remote Service box.
Refitting
Use this procedure to refit the Remote Service box.
248
Action
1.
DANGER!
Before commencing any work inside the
cabinet, please observe the safety information
in section
DANGER - Make sure that the main
power has been switched off! on page
2.
WARNING!
The unit is sensitive to ESD, before handling
the unit please observe the safety information
in section The unit is sensitive to ESD! on page
27.
3. Disconnect all connectors from the Remote
Service box.
4. Push the spring locks in the arrow direction
and lift the box out.
Action
1.
DANGER!
Before commencing any work inside the
cabinet, please observe the safety information
in section
DANGER - Make sure that the main
power has been switched off! on page
Note/illustration
30.
xx0800000091
A: Spring lock
Note/illustration
30.
Continues on next page
3HAC021313-001 Revision: P