Motorola iDEN Site Controller System Manual page 142

Gen 3
Table of Contents

Advertisement

Chapter 6 System Testing
Site Controller Verification
6-10
At the ACG# prompt, type: install
6.
After it is initialized, the following message is displayed:
7.
ACG# install
NVRAM is o.k. - calc = 1373883506, stored = 1373883506
Integrated Site Controller
Copyright Motorola Inc. 2000
Software Version:
Active/Standby Status:
GPS Status
Site Reference ISA
ROM checksum test performed
RAM checksum test performed
Correlation test for the channels performed
Satellite tracking status
Frequency Lock status
GPS Alarm status
Environmental Alarm Unit (EAS)
Ethernetnot available
Internal Loopback Test
T1 initialization
Subrated E1 Network Interface 1:Available
Subrated E1 Network Interface 2:Available, but has LOSS OF SIGNAL
Subrated E1 Network Interface 3:Available, but has LOSS OF SIGNAL
Subrated E1 Network Interface 4:Available, but has LOSS OF SIGNAL
isc>
Gen 3 Site Controller System Manual
RXX.XX.XX-ACG_INSTALL
ACTIVE
available
unknown
unknown
unknown
unknown
unknown
alarm
not available
fail
OK
68P80801E30-A 5/1/2002