Site Controller Startup Sequence - Motorola iDEN Site Controller System Manual

Gen 3
Table of Contents

Advertisement

Gen 3 Site Controller System Manual

Site Controller Startup Sequence

68P80801E30-A 5/1/2002
Connect an RS-232 cable from the serial port on the service
1.
computer to "Service Access" connector on the front of
Controller A.
Apply power to the service computer.
2.
After the service computer initializes, the first prompt on the screen
identifies the hard drive name. This is most commonly the C:\ drive, but
can vary depending on what type of computer is used and how it is
configured.
C:\>
The service computer must contain serial port communications
Note:
software (e.g. ProComm plus).
The following procedures are written for DOS-based service
computers. For Macintosh service computers, alternate procedures
are available from your iDEN System Manager .
Invoke the communications program by typing:
3.
C:\IDEN> procomm
Using the communications software, configure the service computer
4.
RS-232 port with the parameters listed in Table 6-2.
Table 6-2
RS-232 port configuration
Description
Baud rate
Parity bit
Data bits
Stop bits
COM port
This procedure may be halted and restarted at any time by powering
Note:
down Controller B and pressing the CPU Reset pushbutton on
Controller A.
Setting
19200
none
8
1
COM1
Chapter 6 System Testing
Site Controller Verification
6-5