Motorola iDEN Site Controller System Manual page 119

Gen 3
Table of Contents

Advertisement

Gen 3 Site Controller System Manual
Table 4-24 Punch block 1 (system alarm) pinouts — continued
Alarm
code
EAS/EAS2 function
247
Major rectifier failure
248
Generator remote start
249
RFC #4 combiner/multicoupler
amplifier
250
RFC #4 combiner/multicoupler
power supply
251
RFC #4 tower top amplifier
253
reserved for system use
254
reserved for system use
Pinout connections in "Punch block 2" column indicate pins where jumpering between punch blocks 1 and 2 is required.
NOTE:
Install jumper from pin specified in "punch block 1" column to the pin specified immediately to the right in "punch block 2"
column. For example, on alarm code 249, jumper is to be installed from punch block 1, pin 20 to punch block 2, pin 27.
68P80801E30-A 5/1/2002
Punch block 2
signal pairs (left side)
(NOTE)
27
2
26
4
29
1
Chapter 4 Installation
Intercabling Connections
Punch block 1
signal pairs (right side)
17
42
6
5
30
20
45
19
44
18
43
26
2
1
28
4
3
4-53