Chapter 9 Controller
Controller
Table 9-1
Front Panel LED's
LED Name
Bottom Row
LOS / OOF
Red
Yellow
Yellow
AIS
Yellow
FE / CRC
Red
BPV / PD
Red
Net
Red
Local
Yellow

Switches

9-4
LED Color
ON: Detected T1 / E1 Loss Of Signal or Out -Of-Frame condition.
OFF: Normal operation.
ON: Detected T1 / E1 yellow alarm.
OFF: Normal operation.
ON: Detected Alarm Indication Signal.
OFF: Normal operation.
ON: Detected Framing Error or CRC error.
OFF: Normal operation.
ON: Detected Bipolar Violation or Pulse Density violation.
OFF: Normal operation.
ON: T1 / E1 Network loopback.
OFF: Normal operation.
ON: T1 / E1 Local loopback.
OFF: Normal operation.
The Controller contains three switches on the front panel:
Power – a toggle switch that applies (position 1) and removes (position 0)
I
power to the Controller
Abort/Reset – a pushbutton switch that aborts or resets the Controller
I
CPU when pressed
Sel/Loop – a pushbutton that selects a span or initiates network loopbacks
I
when pressed
Gen 3 Site Controller System Manual
Function
68P80801E30-A 5/1/2002