Site Controller Cabling; Table C-1 T1 Site Controller Cabling - Motorola iDEN Site Controller System Manual

Gen 3
Table of Contents

Advertisement

Appendix C Cabling Diagrams

Site Controller Cabling

Site Controller Cabling
Table C-1
T1 Site Controller cabling
Index
Part
number
number
1
3083609X01
2
3082082X02
3
3082004X02
4
3082004X02
5
3082004X02
6
5882669Y01
7
5882669Y01
8
5882669Y01
9
5882669Y01
10
5882669Y01
C-2
Site controller cabling refers to the cable connections between the Circuit
Breaker Panel, Junction Panel, EAS/EAS2, Controller A, and Controller B.
Table C-1 identifies and Figure C-1 and Figure C-2 show standard T1 site
controller cabling.
From
CTL A EAS connector
on Circuit Breaker
Panel
CTL B connector on
Circuit Breaker Panel
ETHERNET 10B2-1
connector on Junction
Panel
ETHERNET 10B2-2
connector on Junction
Panel
ETHERNET 10B2-3
connector on Junction
Panel
10B2-1 connector on
Controller A
10B2-2 connector on
Controller A
10B2-3 connector on
Controller A
10B2-1 connector on
Controller B
10B2-2 connector on
Controller B
To
Bat connector on
Controller A
Battery connector on
EAS/EAS2
Bat connector on
Controller B
Y-connector tap on
Controller A, 10B2-1
Connector
Y-connector tap on
Controller A, 10B2-2
Connector
Y-connector tap on
Controller A, 10B2-3
Connector
-
-
-
-
Gen 3 Site Controller System Manual
Notes
Y-cable that supplies power to
Controller A and the EAS/EAS2
supplies power to Controller B
BNC Y-connector
BNC Y-connector
BNC Y-connector
BNC Y-connector
BNC Y-connector