Siemens SINAMICS S120 Device Manual page 197

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Order no.
SCCR (short circuit current rating)
Minimum short-circuit current
The base load current I
1)
300 s.
The current demand for the 400 V AC and 230 V AC auxiliary supplies is provided by the line supply input voltage.
2)
The specified power loss represents the maximum value at 100 % capacity utilization. The value in normal operation is
3)
lower.
Total sound pressure level of Active Interface Module and Active Line Module.
4)
Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request, see
5)
SINAMICS - Low Voltage Configuration Manual on the customer DVD supplied with the device.
The cabinet height increases by 10" (250 mm) with degree of protection IP21, and by 16" (400 mm) with degrees of
6)
protection IP23 (NEMA1 filtered), IP43, and IP54 (NEMA12 ventilated).
Minimum current required for reliable tripping of the contained protective devices.
7)
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A
6SL3730-
kA IC
A
7)
is based on a duty cycle of 150 % for 60 s or I
H DC
5.4 Active Line Modules including Active Interface Modules
7TE36-
7TE38-
1AU3
4AU3
65
84
12000
2000
for 5 s with a duty cycle duration of
max DC
Cabinet Modules
7TE41-
7TE41-
0AU3
4AU3
84
100
4000
6400
197

Advertisement

Table of Contents
loading

Table of Contents