Cabinet Modules
5.6 Motor Modules in chassis format
5.6.2.3
X46 Brake control and monitoring
Table 5- 34
Terminal strip X46 brake control and monitoring
Terminal
1
2
3
4
Max. connectable cross-section: #14 AWG (2.5 mm
Fire hazard due to overheating when permissible connection cable lengths are exceeded
Excessively long connection cables connected to terminal strip X46 can cause components
to overheat with the associated risk of fire and smoke.
• Limit the length of the connected cables to a maximum of 33 ft (10 m).
• Do not route the connection cable outside the control cabinet or control cabinet group.
5.6.2.4
DRIVE-CLiQ interfaces X400, X401, X402
Table 5- 35
DRIVE-CLiQ interfaces X400, X401, X402
PIN
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interfaces (50 pcs.) Order number: 6SL3066-4CA00-0AA0
224
Function
BR output +
BR output -
FB input +
FB input -
WARNING
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical specifications
This interface is intended for the connection of the Safe Brake
Adapter.
)
2
Technical specifications
Send data +
Send data -
Receive data +
Receive data -
24 V power supply
Electronics ground
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A