K51, Vsm10 Voltage Sensing Module Cabinet-Mounted - Siemens SINAMICS S120 Device Manual

Cabinet modules nema
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options

8.12 K51, VSM10 Voltage Sensing Module Cabinet-Mounted

Connection example 2: TTL encoder, unipolar, without zero track -> p0405 = A (hex)
Figure 8-21
8.12
K51, VSM10 Voltage Sensing Module Cabinet-Mounted
Availability of option
This option is available for the following S120 Cabinet Modules:
● Booksize Cabinet Kits
● Motor Modules in chassis format
Description
The VSM10 Voltage Sensing Module is used for operation of a permanent-field synchronous
machine without encoder with the requirement for starting in a running machine (flying restart
function).
The terminals on the Voltage Sensing Module (-T1-B51) are pre-assigned in the factory and
must not be changed by the customer.
For commissioning, the permanent-field synchronous machine without encoder must be
entered, and the "flying restart" function must be activated via p1200.
386
Connection example 2: TTL encoder, unipolar, without zero track
Cabinet Modules NEMA
Manual, 04/2014, A5E03586450A