Options

8.9 K46, Sensor Module Cabinet-Mounted SMC10

Features
● Display with green backlighting (resolution: 240 x 64 pixels)
● 26-key keypad
● RS 232 interface
● Time and date memory powered by internal battery backup
● 4 LEDs indicate the operating state of the drive unit:
RUN, green
ALARM, yellow
FAULT, red
LOCAL/REMOTE, green
Note
Additional documents
Detailed and comprehensive instructions and information for the AOP30 Advanced Operator
Panel can be found in the relevant operating instructions. These operating instructions are
available as additional documentation on the customer DVD supplied with the device.
→ See additional documentation "SINAMICS S120 Cabinet Module AOP30"
8.9
K46, Sensor Module Cabinet-Mounted SMC10
8.9.1

General information

Availability of option
This option is available for the following S120 Cabinet Modules:
● Booksize Cabinet Kits
● Motor Modules in chassis format
Description
The SMC10 Sensor Module is used for determining the actual motor speed and the rotor
position angle. The signals emitted by the resolver are converted here and made available to
the closed-loop controller via the DRIVE-CLiQ interface for evaluation purposes.
The following encoders can be connected to the SMC10 Sensor Module:
● 2-pin resolver
● Resolver, multi-pole
The motor temperature can also be detected using KTY84-130 temperature sensors or PTC
thermistors.