Mounting
5.3 Mounting with built-in ring light and EF lens
Mounting the individual components
Figure 5-4
Proceed as follows to mount the SIMATIC MV540 optical reader with built-in ring light, lens
and protective lens barrel:
1. Remove the protective foil from the reader.
2. Mount the ring light holder ②.
– When using a 50 mm EF lens, make sure that you use the suitable ring light holder and
– Make sure that the ring light holder is aligned correctly and fully flush when it is
– Fasten the ring light holder ② with the three hexagon socket screws ④ onto the
3. Insert the straight connector of the lens cable into the interface of the reader (a).
4. When using EF lenses with 12 and 16 mm focal length (6GF3540-8EA01-0LL0 and
6GF3540-8EA02-0LL0):
Screw the spring/lock ring into the lens mount of the reader.
5. Screw the desired lens ① into the lens mount of the reader ③.
Ensure the correct alignment of the lens so that the interface is close to the
cutout/interface (a). If needed, unscrew the lens slightly. If needed, align the lens using
the knurled nut/spring/counter ring.
6. Use the lens cable to connect the EF lens to the reader ③.
Insert the angled connector of the lens cable into the interface of the lens and the straight
connector into the interface of the reader. Ensure that the cable does not become twisted.
108
Lens
Ring light holder
MV540 optical reader
M2.5 hexagon socket-head screws (3x)
Setup of SIMATIC MV540 optical reader with built-in ring light, EF lens and protective lens
barrel
protective lens barrel.
mounted.
reader (≤ 0.45 Nm).