Image processing
3.2 Code verification
Field name (String input)
Start quiet zone (q29)
Stop quiet zone (q30)
Nominal module size (q10)
Aspect ratio 1 (q31)
Aspect ratio 2 (q32)
Aspect ratio 3 (q33)
Height (q15)
Width (q16)
Angle (q17)
3.2.9.7

Standard report for DotCode

Table 3- 16
Field name (String input)
Verification type (Qt)
Evaluation (Qs)
Overall grade (Q0)
Contrast grade (Q1)
Contrast (q1)
Grid non-uniformity grade (Q3)
Grid non-uniformity (q3)
Unused error correction grade (Q4)
Unused error correction (q4)
Print growth grade (Q9)
Print growth (q9)
Cell size grade (Q10)
Cell size (q10)
3.2.9.8

Standard report for Locator

The standard report uses Locator grades when Locator steps are used.
Table 3- 17
Field name (String input)
Verification type (Qt)
Match (q50)
Conformity (q51)
74
Output parameters: DotCode
Output parameters: Locator
Value
10 values: 0.00 ... 10.00
10 values: 0.00 ... 10.00
0 to 99.9 mil
1.00 ... 5.00
1.00 ... 5.00
1.00 ... 5.00
0 to 9.99 inches
0 to 9.99 inches
0 ... 360°
Value
9
3 (Good), 2 (Fair), 1 (Poor)
4 ... 0
4 ... 0
0 ... 100%
4 ... 0
0.00 ... 1.00
4 ... 0
0.00 ... 1.00
4 ... 0
0.00 ... 1.40
4 ... 0
0.0 ... m.n pixels
Value
8
0 ... 100
0 ... 100
Operating Instructions, 03/2021, C79000-G8976-C494-05