Connection
6.3 Connecting the reader
Table 6- 3
Pin
1
2
3
4
Figure 6-5
Table 6- 4
Pin
1
2
3
4
5
6
7
8
Note
Cable assembly for connection to IE RJ45 interface
To connect the "X2 LAN2" interface (M12, 8-pin) with an IE RJ45 interface, you need to
replace one of the M12 connectors of the cable "6XV1878-5Gxxx" with the IE connector FC
RJ45 ("6GK1901-1BB12-2AA0"). For strain relief to be guaranteed, you need to enlarge the
assembled cable to a length of approx. 5 - 10 cm behind the replaced connector using an
adhesive tape to Ø 8.
122
Industrial Ethernet connecting cable M12 (male, 4-pin) / M12 (male, 4-pin)
Wire color
Signal name
Yellow
TxD_P
White
RxD_P
Orange
TxD_N
Blue
RxD_N
Pin assignment of "X2 LAN2" Ethernet socket (M12, 8-pin) ②
Industrial Ethernet connecting cable M12 (male, 8-pin) / M12 (male, 8-pin)
Wire color
Signal name
Orange/white
TxD/RxD+2
Orange
TxD/RxD-2
Green/white
TxD/RxD+1
Green
TxD/RxD-1
Brown/white
TxD/RxD+3
Brown
TxD/RxD-3
Blue/white
TxD/RxD+4
Blue
TxD/RxD-4
Meaning
Send data +
Received data +
Send data -
Received data -
Operating Instructions, 03/2021, C79000-G8976-C494-05