Service and maintenance
10.1 Error and diagnostics messages
LED
Meaning
labeling
ER
Red, permanently on:
The optical reader is in "Group error" mode
Possible causes when working with onboard
PROFINET IO:
Bus communication is interrupted.
Bus error (no physical connection to a
subnet / switch).
Wrong transmission speed,
Full duplex transmission is not enabled.
The IP address is incorrect.
Bad configuration.
Bad parameter assignment.
Bad or missing device name.
I/O controller not available / switched off.
R/S
Permanently off:
The optical reader is in "Stop" mode.
Green, permanently on:
The optical reader is in "RUN" mode.
LK
Permanently off:
There is no Ethernet connection to the opti-
cal reader.
Green, permanently on:
An Ethernet connection without data traffic
is available.
Green flashing:
The optical reader is exchanging data.
READ
Green flashing:
The read result is valid.
Yellow, flashing:
The read result ended with a MATCH error.
Red, flashing:
The read result is invalid (N_OK).
234
Description and corrective measures
Start the WBM to view the error message. Perform the sug-
gested corrective measures in the section "Error messages
(Page 224)".
Check whether the IP address or device name occurs
more than once in the network.
Check the settings of the I/O controller.
No error
No error
Check the connection to the Ethernet cable.
Check whether the connected switch or other communi-
cations partner is operational.
Check or replace the Ethernet cable.
In order to start the WBM of the optical reader, you also
need a valid network configuration for TCP/IP. Here, for
example, you can use the SINEC PNI to create a valid net-
work configuration for TCP/IP.
No error
No error
The reading was successful and the read result is valid (OK).
The reading was successful, but the result comparison
showed a deviation from the default (MATCH error).
The reading was unsuccessful or the read result is not valid
(N_OK).
Possible causes:
The expected codes were not in the image.
The processing time was not sufficient.
A test condition could not be fulfilled.
Operating Instructions, 03/2021, C79000-G8976-C494-05