10.1.5

Filter error messages

If a filter error occurs, the following error messages are output. You can find additional
information in the section "Overall result" of the online help.
Table 10- 4
Error message
(%s)
Symbol does not use GS1-
encoding
"[Number]" is no valid GS1 Ap-
plication Identifier
GS1 Application Identifier
"[Number]" not found in symbol
content
Symbol content shorter than
given "start position"
ID or separator not found in
symbol content
10.1.6

Diagnostics via the LED display

The operating states of the optical reader are indicated by the LEDs "POWER" (PWR), "ERROR"
(ER), "RUN/STOP" (R/S), "LINK" (LK), "CONNECT" and "READ". The LEDs can adopt the colors
green, red or yellow and the states off , on
Table 10- 5
Display of operating states
LED
Meaning
labeling
PWR
Green flashing:
Signals the startup phase after switching
on the optical reader.
Indicates an active firmware update that
must not be interrupted.
Green, permanently on:
The optical reader is ready for operation
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Filter error messages
For filter mode only
GS1
GS1
GS1
Position
ID
10.1 Error and diagnostics messages
Description
The code read does not begin with the GS1
start symbol "]d2".
The string selected in the "Filter ID" box
contains an invalid application identifier
tag.
An application identifier specified in the
"Filter ID" box was not found in the read
code.
The read code is shorter than the selected
"Start position"
An ID (field: "Filter ID") or a separator char-
acter (field: "Separators") was not found in
the read code.
, flashing :
Description and corrective measures
Wait until this is completed and the optical reader is opera-
tional.
No error