3.2.9.2

Standard report for ISO/IEC 15415

Table 3- 11
Field name (String input)
Verification type (Qt)
Evaluation (Qs)
Overall grade (Q0)
Reference decode grade (Q7)
Contrast grade (Q1)
Contrast (q1)
Axial non-uniformity grade (Q2)
Axial non-uniformity (q2)
Grid non-uniformity grade (Q3)
Grid non-uniformity (q3)
Unused error correction grade (Q4)
Unused error correction (q4)
L/F border violation grade (Q5)
Modulation grade (Q6)
Print growth X (q9)
Print growth Y (q9)
Cell size (q10)
Aperture (q12)
ECCLevel (q14)
Height (q15)
Width (q16)
Angle (q17)
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Output parameters: ISO/IEC 15415
Value
2
If the exposure settings do not comply with the
standard: C
3 (Good), 2 (Fair), 1 (Poor)
4 ... 0
4 ... 0
4 ... 0
0 ... 100
4 ... 0
0.00 ... 1.00
4 ... 0
0.00 ... 1.00
4 ... 0
0.00 ... 1.00
4 ... 0
4 ... 0
-100 ... 100
-100 ... 100
0 ... 99.9 mil
0, 4 ... 20 mils
(0 corresponds to automatic)
200
0 ... 9.99 inch
0 ... 9.99 inch
0 ... 360°