Belt Maintenance

Tensioning the Alternator
Belt
Service Interval: After the first 8 hours—Check
the condition and tension of the
alternator belt.
Every 100 hours
1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Open the hood; refer to
43).
3.
Check the tension of the alternator belt by
pressing it
(Figure
alternator and the crankshaft pulleys with 10 kg
(22 lb) of force.
Note:
The belt should deflect 11 mm (7/16
inch). If the deflection is incorrect, proceed to
step 4. If belt tension is correct, skip to step 7.
Figure 116
1. Brace
2. Alternator belt
4.
Loosen the bolt securing the alternator to the
brace, and the alternator pivot bolt.
5.
Insert a pry bar between the alternator and the
engine and move the alternator outward.
6.
When the belt is tensioned as described in step
3, tighten the bolts securing the alternator to the
brace, and the alternator pivot bolt.
7.
Close and latch the hood; refer to
Hood (page
43).
43).
Opening the Hood (page
116) midway between the
3. Pivot bolt
(Figure
Closing the
Hydraulic System
Maintenance

Hydraulic System Safety

Seek immediate medical attention if fluid is injected
into skin. Injected fluid must be surgically removed
within a few hours by a doctor.
Ensure that all hydraulic-fluid hoses and lines are
in good condition and all hydraulic connections
and fittings are tight before applying pressure to
the hydraulic system.
Keep your body and hands away from pinhole
leaks or nozzles that eject high-pressure hydraulic
fluid.
Use cardboard or paper to find hydraulic leaks.
Safely relieve all pressure in the hydraulic system
before performing any work on the hydraulic
system.
Hydraulic Fluid
Specification
The reservoir is filled at the factory with high-quality
hydraulic fluid. Check the level of the hydraulic fluid
before you first start the engine and daily thereafter;
refer to
Checking the Hydraulic-Fluid Level (page
Recommended hydraulic fluid: Toro PX Extended
Life Hydraulic Fluid; available in 19 L (5 US gallon)
pails or 208 L (55 US gallon) drums.
Note:
A machine using the recommended
replacement fluid requires less frequent fluid and filter
changes.
Alternative hydraulic fluids: If Toro PX Extended
Life Hydraulic Fluid is not available, you may use
another conventional, petroleum-based hydraulic fluid
having specifications that fall within the listed range
g003976
for all the following material properties and that it
meets industry standards. Do not use synthetic fluid.
Consult with your lubricant distributor to identify a
satisfactory product.
Note:
Toro does not assume responsibility for
damage caused by improper substitutions, so use
116)
products only from reputable manufacturers who will
stand behind their recommendation.
High Viscosity Index/Low Pour Point
Anti-wear Hydraulic Fluid, ISO VG 46
Material Properties:
Viscosity, ASTM D445
67
68).
cSt @ 40°C (104°F)
44 to 48