Siemens SICHARGE UC Operating Instructions Manual page 34

Table of Contents

Advertisement

SICHARGE UC Dispenser UL | Operating Instructions
Selection criteria for a safe location
Select the location of the SICHARGE UC dispenser so that all charging actions are safe.
The user must be able to connect the vehicle without using extension cables. This means that the
SICHARGE UC dispenser must be located in the close vicinity of the mounting surfaces to be supplied.
The SICHARGE UC dispenser must not pose a risk to persons or vehicles.
Properties of the mounting surface
• Floor mounting:
To ensure the stability of the SICHARGE UC dispenser, the floor space must meet the following requirements:
– Level
– Dry
– Sufficiently strong and able to bear the weight the dispenser
Note
Sealing the mounting plate
Seal the mounting plate and the cable openings in the foundation with suitable materials to prevent
moisture, animals, and insects from getting inside the station.
• Wall mounting:
To ensure a secure hold of the SICHARGE UC dispenser, the mounting surface must meet
the following requirements:
– Level
– Dry
– Sufficiently solid and stable
– Take into account the static of building
You can find the dimensions for assembly in the section Preparing the mounting surface (Page 39).
Additional data can be found in the section Technical specifications (Page 106).
34

Advertisement

Table of Contents
loading

Table of Contents