Siemens SICHARGE UC Operating Instructions Manual page 82

Table of Contents

Advertisement

SICHARGE UC Dispenser UL | Operating Instructions
"Energy Delivered During Last Charging Session" menu
The touch screen displays the following information for the current charging process in the "Energy
Delivered During Last Charging Session" menu:
Figure 8-12 "Energy Meter" menu
Value
Description
Start Date
Specifies the start date and time of the charging process.
Initial SoC
Indicates the initial state of charge (SoC) of the vehicle battery.
End Date
Indicates the end date and time of charging.
Final SoC
Displays the final state of charge (SoC) of the vehicle battery.
Energy
Indicates the amount of energy transferred to the electric vehicle during
Delivered
charging.
Alarm Code
The charging station displays the following alarm codes:
• Value "0": The SICHARGE UC dispenser has completed the charging process
• Values "1" to "43": The SICHARGE UC dispenser has aborted the charging
82
without errors.
process prematurely with an alarm. You can find a list of the alarm messages
in the section Alarm messages in the Alarm History (Page 92).