Displaying Energy Delivered During The Last Charging Session - Siemens SICHARGE UC Operating Instructions Manual

Table of Contents

Advertisement

Voltage and current values
For the charging station, the touch screen of the displays the following values:
Value
Input voltage A-N
Input voltage B-N
Input voltage C-N
Input current A
Input current B
Input current C
DC link voltage
Buck output voltage
Frequency
Output power
Current reduction
Output energy
8.7.5 Displaying energy delivered during last charging session
The SICHARGE UC dispenser has an energy meter. The energy meter provides you with basic information
on the current charging process.
Requirements
• You have opened the "Options" menu.
• You have pressed the "Last Session Energy Delivered" button in the "Options" menu.
Meaning
AC voltage measured in line conductor A-N
AC voltage measured in line conductor B-N
AC voltage measured in line conductor C-N
AC current measured in line conductor A
AC current measured in line conductor B
AC current measured in line conductor C
Voltage measured at the internal DC bus
Voltage measured at the DC output
Current frequency
Calculated current output power
Amount of derating at the charger output
Calculated energy during charging
Operating Instructions | SICHARGE UC Dispenser UL