Wall Mounting; Mounting The Dispenser To The Wall - Siemens SICHARGE UC Operating Instructions Manual

Table of Contents

Advertisement

SICHARGE UC Dispenser UL | Operating Instructions
Mounting the SICHARGE UC dispenser
To position the SICHARGE UC dispenser on the base area, follow these steps:
1. Position the SICHARGE UC dispenser on the mounting surface using the bolt anchors.
2. Guide any underground cables into the mounting base of the SICHARGE UC dispenser.
3. Check whether the alignment of the SICHARGE UC dispenser with the bolt anchors of the mounting surface is correct.
4. Lower the SICHARGE UC dispenser onto the base area.
5. Place the washers on the bolt anchors.
6. Attach a bolt lock to the bolt anchors. We recommend Loctite 243.
7. Screw the cap nuts onto the bolt anchors.
8. Tighten the nuts with the tightening torque of the bolt anchors per the manufacturer's instructions.
9. Seal the openings from the mounting surface to the mounting plate with a suitable sealant to prevent the ingress of moisture,
animals, and insects.
10. Remove the two transport plates on the rear of the SICHARGE UC dispenser. Keep the transport plates.

5.3 Wall mounting

5.3.1 Mounting the dispenser to the wall

Due to the variety of options, the total weight of the SICHARGE UC dispenser is different, depending on the equipment.
To mount the SICHARGE UC dispenser at the location, you must lift the SICHARGE UC dispenser off the transport pallet. If the
SICHARGE UC dispenser is heavy, transport it to the prepared mounting area using a forklift.
Lifting the SICHARGE UC dispenser
The SICHARGE UC dispenser wall/ceiling mounting is delivered with mounting rails on the rear of the device.
To lift the SICHARGE UC dispenser off the transport pallet, follow these steps:
1. Mount the shackle into the holes on the right and left of the mounting rail.
2. Attach the shackles to the lifting equipment. Only use suitable and approved lifting equipment.
3. Lift the SICHARGE UC dispenser vertically from the transport pallet.
4. Transport the SICHARGE UC dispenser suspended to the location.
50

Advertisement

Table of Contents
loading

Table of Contents