5. PARAMETERS

5. PARAMETERS
CAUTION

5.1 Parameter list

5.1.1 Parameter write inhibit

In the servo amplifier, its parameters are classified into the basic parameters (No.0 to 19) and
expansion parameters (No.20 to 66) according to their safety aspects and frequencies of use. In the
factory setting condition, the customer can change the basic parameter values but cannot change the
expansion parameter values. When fine adjustment, e.g. gain adjustment, is required, change the
parameter No.19 setting to make the expansion parameters write-enabled.
The following table lists the parameters whose values are made valid for reference/write by setting
parameter No. 19. Operation can be performed for the parameters marked
Parameter No.19 Setting
0000
(initial value)
000A
000B
000C
000E
Downloaded from
ManualsNet.com
Never adjust or change the parameter values extremely as it will make operation
instable.
POINT
Set "000E" when using the Servo Configuration Software to make device
setting.
After setting the parameter No.19 value, switch power off, then on to
make that setting valid.
Operation
Reference
Write
Reference
Write
Reference
Write
Reference
Write
Reference
Write
search engine
Basic Parameters
Expansion Parameters
No.0 to 19
No.20 to 53
No.19 only
No.19 only
5 - 1
.
Expansion Parameters
No.54 to 66