Gain Adjustment; Parameters Required For Gain Adjustment; Block Diagram - Mitsubishi Electric MELSERVO-J2 Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

9. ADJUSTMENT

9.2 Gain adjustment

9.2.1 Parameters required for gain adjustment

Parameter No.
3
7
22
34
35
36
37
38

9.2.2 Block diagram

The block diagram of the servo amplifier servo control section is shown above. (The current loop is
omitted.)
Command
(1) Actual loop section
A control loop designed to control the actual motor and acts to control the servo system stably in
response to the load torque of the machine.
(2) Model section
Acts to provide the ideal operation values to the current loop in response to the command.
(3) Auto tuning section
Judges the load inertia moment of the machine fitted with the actual motor from the operation error of
the motor to change each control gain in real time.
The gains changed by auto tuning are PG1, VG1, PG2, VG2 and VIC.
Downloaded from
ManualsNet.com
Symbol
ATU
Auto tuning
PG1
Position loop gain 1
*OP4
Function selection 4 (machine resonance filter)
GD2
Ratio of load inertia moment to motor inertia moment
PG2
Position loop gain 2
VG1
Speed loop gain 1
VG2
Speed loop gain 2
VIC
Speed integral compensation
PG1
VG1
PG2
search engine
Name
Virtual motor
Auto tuning
section
OP4
Motor
VG2
Notch filter
VIC
9 - 3
J
ENC
M
Model
Virtual encoder
section
Machine
L
Encoder
J
ENC
M
Actual loop

Advertisement