Mitsubishi Electric MELSERVO-J2 Series Instruction Manual page 76

Servo amplifier
Table of Contents

Advertisement

4. OPERATION
(2) Startup procedure
(a) Power on
1) Switch off the servo-on (SON).
2) When main circuit power/control circuit power is switched on, "r" (motor speed) appears on the
servo amplifier display.
In the absolute position detection system, first power-on results in the absolute position lost
(A.25) alarm and the servo system cannot be switched on. This is not a failure and takes place
due to the uncharged capacitor in the encoder.
The alarm can be deactivated by keeping power on for a few minutes in the alarm status and
then switching power off once and on again.
Also in the absolute position detection system, if power is switched on at the servo motor speed
of 500r/min or higher, position mismatch may occur due to external force or the like. Power must
therefore be switched on when the servo motor is at a stop.
(b) Test operation
Using jog operation in the test operation mode, operate at the lowest speed to confirm that the
servo motor operates. (Refer to Section 6.7.1.)
(c) Parameter setting
Set the parameters according to the structure and specifications of the machine. Refer to Chapter 5
for the parameter definitions and to Sections 6.4 and 7.6 for the setting method.
Parameter
No.0
No.1
No.2
No.4
No.5
After setting the above parameters, switch power off once. Then switch power on again to make the
set parameter values valid.
(d) Point table setting
Set the point table according to the operation pattern. Refer to Section 4.2 for the point table
definitions and to Sections 6.5 and 7.5 for the setting method.
Position Data
[ 10
20000
(e) Servo-on
Switch the servo-on in the following procedure:
1) Switch on main circuit/control circuit power.
2) Switch on the servo-on (SON).
When placed in the servo-on status, the servo amplifier is ready to operate and the servo motor is
locked. By using the sequence in the diagnostic mode in Section 7.3, the ready status can be shown
on the servo amplifier display. In the operation-ready status, the following screen appears.
Downloaded from
ManualsNet.com
Name
Command system, regenerative
brake option selection
Feeding function selection
Function selection 1
Electronic gear numerator (CMX)
Electronic gear denominator (CDV)
Servo Motor Speed
STM
m]
[r/min]
2500
search engine
Setting
20
10
1
8192
From calculation result of formula (4.1)
5000
From calculation result of formula (4.1)
Acceleration Time Constant
Deceleration Time Constant
[ms]
200
4 - 3
Description
Absolute value command system.
MR-RB032 regenerative brake option
is used.
When forward rotation start (ST1) is
valid, address is incremented in CCW
direction.
Since command resolution is 10 times,
feed length multiplication factor of 10
times is selected.
Absolute position detection system.
Dwell Time
[ms]
[ms]
300
0
Auxiliary
Function
0