11. Press and hold the button (C) to fill hydraulic oil.
PRESS AND HOLD TO ACTIVATE. RELEASE
BUTTON TO STOP
12. Examine the hydraulic oil level in the sight glass on
the hydraulic oil tank. The hydraulic oil level must not
be more than 1 cm/0.39 in. below the maximum
level.
13. Release the button (C) when the hydraulic oil is at
the correct level in the sight glass.
14. Remove the suction hose from the hydraulic oil
container.
15. Install the plug of the suction hose.
16. Close the left hatch on the product.
17. Start the product. Refer to
275, DXR 305, DXR 315) on page 53 .
18. Move the arm system between outer and inner end
position some times to remove air in the hydraulic
system.
19. Stop the product and make sure that there are no
leaks.
1401 - 002 - 15.10.2021
C
12%
OIL
REFILL
MAX
MIN
To start the product (DXR
20. Examine the hydraulic oil level in the sight glass on
the hydraulic oil tank. Fill with hydraulic oil if it is
necessary.
To replace the hydraulic oil filter (DXR
145)
WARNING:
hydraulic oil becomes hot during operation
of the product. Let the product become cool
before you replace the hydraulic oil filter.
1. Park the product on level ground.
2. Stop the product. Refer to
145) on page 62 .
3. Remove the 4 screws and the front cover.
4. Clean the area around the air filter.
Risk of burn injury. The
To stop the product (DXR