Download Print this page

Troubleshooting - Husqvarna DXR 145 Operator's Manual

Hide thumbs Also See for DXR 145:

Advertisement

To do after maintenance
1. Do a test operation after maintenance is done.
WARNING:
damage. Incorrectly installed remote
control, cables or hoses can have an

Troubleshooting

Problem
The product does not
start.
The fuses for the
mains connection
blow immediately af-
ter starting the prod-
uct.
1401 - 002 - 15.10.2021
Risk of injury and
Troubleshooting
Cause
The main switch is off.
The extension cable is disconnected or dam-
aged.
The emergency stop button on the product is
engaged.
The machine stop button on the remote con-
trol is engaged.
Too low mains voltage to the product.
A mains fuse is blown.
No radio communication between the prod-
uct and the remote control.
The fuse for the mains connection have too
low rating value.
The electric motor is defective.
The power cord is defective.
The hydraulic pump is defective.
unwanted effect on the movements of
the product.
2. If there is a fault, immediately stop the product. Refer
to
To stop the product (DXR 145) on page 62 and To
stop the product (DXR 275, DXR 305, DXR 315) on
page 62 .
Solution
Do a check of the main switch.
Connect the extension cable. Replace the
extension cable if it is damaged.
Turn the emergency stop button on the prod-
uct clockwise to disengage.
Turn the machine stop button on the remote
control clockwise to disengage.
Do a check of the power supply. Make sure
that correct voltage is used.
Make sure that the mains voltage is compati-
ble with the product and that the correct
fuses are used.
Do a check of the power cord.
Do a check of the radio signal. If there is no
radio signal, examine if the batteries for the
remote control are charged and correctly in-
stalled.
Make sure that correct remote control is
used.
Make sure that the communication cable and
the antenna cable on the product are correct-
ly attached.
Do a test operation of the product with a ca-
ble between the product and the remote con-
trol.
Make sure that the mains voltage is compati-
ble with the product and that the correct
fuses are used.
Speak to an approved service agent.
Replace the power cord.
Speak to an approved service agent.
91

Advertisement

loading

This manual is also suitable for:

Dxr 275Dxr 305Dxr 315