Fault code number
133
134
135
170
171
172
173
174
175
176
177
178
179
180
1401 - 002 - 15.10.2021
Message in the dis-
play
"Cable error Loss of
function"
"Cable error Loss of
function"
"Cable error Loss of
function"
"Safety PLC error
Safety Stop"
"Oil pressure sensor
Safety Stop"
"Oil pressure sensor
Safety Stop"
"System pressure
Safety Stop"
"Contactor error
Safety Stop"
"Contact error Safety
Stop"
"Remote control error
Safety Stop"
"Emergency STOP
pressed Safety Stop"
"Emergency STOP
error Safety stop"
"Machine stop Safety
Stop"
"Remote control error
Safety Stop"
Cause
The cable for the pressure con-
trol valve is damaged.
The cable for the tower rotate
valve is damaged.
The cable for the tower rotate
valve is damaged.
-
-
-
-
-
-
-
Emergency STOP button is
pushed.
The cable for the Emergency
STOP button is damaged.
The machine stop button is push-
ed on the remote control.
-
Solution
Speak to Husqvarna service.
Speak to Husqvarna service.
Speak to Husqvarna service.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the emergency stop button
clockwise to disengage.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
Turn the emergency stop button
on the remote control clockwise,
to disengage the emergency
stop.
Turn the main switch to ON and
then to OFF. If the problem
stays, speak to Husqvarna serv-
ice.
99

Advertisement

loading

This manual is also suitable for: