Class3 Message Communications Communication
Example
This section describes an example of executing Class3 message communications between CC-Link IE TSN Plus modules.

System configuration

The following system configuration is used to explain the communication example of Class3 message communications.
(1)
(1) Programmable controller system (client)
• Power supply module: R61P
• CPU module: R04CPU
• CC-Link IE TSN Plus module: RJ71GN11-EIP (start I/O number: 0000H to 001FH, IP address: 192.168.4.10)
(2) Programmable controller system (server)
• Power supply module: R61P
• CPU module: R04CPU
• CC-Link IE TSN Plus module: RJ71GN11-EIP (start I/O number: 0000H to 001FH, IP address: 192.168.4.11)

Setting parameters

Use the engineering tool to set the parameters.
Setting the CC-Link IE TSN Plus module (client)
Connect the engineering tool to the client-side CPU module and set the parameters.
1.
Set the CPU module as follows.
[Project]  [New]
2.
Click the [Setting Change] button to use the module label.
13 PROGRAMMING
328

13.5 Class3 Message Communications Communication Example

(2)