Error
Error definition and causes
code
3C02H
A hardware failure has been detected.
3C0FH
A hardware failure has been detected.
3C10H
A hardware failure has been detected.
3C13H
A hardware failure has been detected.
3C14H
A hardware failure has been detected.
3C2FH
An error was detected in the memory.
3E01H
Network type of the own station is
unexpected setting.
3E02H
A time synchronization error was detected.
3E03H
An error was detected in the memory.
3E04H
A hardware failure has been detected.
3E07H
A hardware failure has been detected.
4000H to
Errors detected by the CPU module ( MELSEC iQ-R CPU Module User's Manual (Application))
4FFFH
C011H
The port number of the external device is
not set correctly.
C012H
The port number used in a connection
already opened is set. (For TCP/IP)
C013H
The port number used in a connection
already opened is set. (For UDP/IP)
C015H
The data was sent to the connected device
while the IP address setting of the device
set in the network configuration setting
was incorrect.
C017H
A connection could not be established in
the open processing.
C018H
The specified IP address of the external
device is incorrect.
C020H
The send/receive data length exceeds the
allowable range.
Action
• Take measures to reduce noise.
• Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of
the module, base unit, or extension cable. Please consult your local
Mitsubishi representative.
• Take measures to reduce noise.
• Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of
the module, base unit, or extension cable. Please consult your local
Mitsubishi representative.
• Take measures to reduce noise.
• Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of
the module, base unit, or extension cable. Please consult your local
Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after taking the above, the possible cause is a hardware failure of the
error module. Please consult your local Mitsubishi representative.
Rewrite the module parameter using the engineering tool. If the same error
occurs again even after taking the above, the possible cause is a hardware
failure of the error module. Please consult your local Mitsubishi
representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Reset the CPU module, and run it again. If the same error occurs again
even after doing so, the possible cause is a hardware failure of the error
module or CPU module. Please consult your local Mitsubishi representative.
Correct the port number of the external device.
Correct the port numbers of the CC-Link IE TSN-equipped module and the
external device.
Correct the port numbers of the CC-Link IE TSN-equipped module and the
external device.
• Correct the IP address of the connected device in the network
configuration setting.
• Check that the IP address class of the connected device is set to A, B, or
C in the network configuration setting.
• Check the operation of the external device.
• Check if the open processing has been performed in the external device.
• When a firewall is set in the external device, check if access is permitted.
• Check if the Ethernet cable is connected properly.
Correct the specified IP address of the external device.
• Correct the data length to be sent.
• When the amount of data to be sent exceeds the limit, divide the data into
smaller chunks to send it.
19 LIST OF ERROR CODES
19.1 Error Codes When a Module Error Occurs
Detailed
information 1
Detailed
information 2
19
415

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn plus

Table of Contents