Dynamic Routing
Select whether to enable the dynamic routing function. ( Page 177 Communications using the engineering tool)
Item
Dynamic Routing
• When the dynamic routing function is enabled, the route is selected according to the status of the
communication path at that time. Even if the dynamic routing function is enabled, if the system contains
devices that do not support dynamic routing (MELSEC-Q/L/QnA/A series products), it is necessary to
configure static routing on the devices that do not support dynamic routing.
• When the dynamic routing function is disabled, the communication route set in the static routing
configuration is used to communicate with different networks.
Precautions
When enabling dynamic routing, do not connect the CPU module (built-in Ethernet port part) and the CC-Link IE TSN Plus
module on the same Ethernet using a switching hub or other means.
Event Reception from Other Stations
Select whether to obtain the events occurring in the other stations.
Item
Event Reception from Other Stations
Module Operation Mode
Set the module operation mode of the CC-Link IE TSN Plus module.
Item
Description
Module
Online
Operation
• Select this mode to connect the CC-Link IE TSN Plus module to the network to perform data link with
Mode
other stations.
Offline
• Select this mode to disconnect the CC-Link IE TSN Plus module from the network and not perform data
link with other stations.
Module Communication Test
• Select this mode to check the hardware of the CC-Link IE TSN Plus module. Select this mode to check
the module hardware when communication is unstable. ( Page 371 Module Communication Test)
*1 EtherNet/IP communications will turn offline.
The following functions are disabled when "Module Operation Mode" is set to "Offline" or "Module
Communication Test". ( Page 138 FUNCTIONS)
• Cyclic transmission
• Transient transmission
• RAS in general
• Event issuance for the interrupt program
• CC-Link IE TSN network synchronous communication
In line topology, data link is not performed for stations connected after a station in offline mode.
Description
When communicating with different networks, select whether to enable the dynamic
routing function.
Description
Select whether to obtain the events occurring in the other stations.
Setting range
• Enable
• Disable
(Default: Enable)
Setting range
• Enable
• Disable
(Default: Enable)
Setting range
• Online
*1
• Offline
• Module Communication Test
(Default: Online)
8 PARAMETER SETTINGS
8.1 Parameter Settings for CC-Link IE TSN
8
87