Download Print this page

Siemens LMV5 Quick Start Manual page 202

Hide thumbs Also See for LMV5:

Advertisement

Function
Address
Number
of
words
03/04
80
2
03/04
82
1
03/04
83
1
Parameters 84...137 are available from AZL5... version V4.20
03/04
84
8
03/04
92
1
03/04
93
1
03/04
94
3
03/04
97
1
03/04
98
8
03/04
106
1
03/04
107
1
03/04
108
3
03/04
111
1
03/04
112
1
03/04
113
1
03/04
114
1
03/04
115
8
03/04
123
1
03/04
124
1
03/04
125
1
03/04
126
1
R 03/04
127
1
W 16
R 03/04
128
1
W 16
03/04
129
1
03/04
130
1
03/04
131
1
03/04
132
1
R 03/04
133
1
W 16
R 03/04
134
1
W 16
R 03/04
135
1
W 16
R 03/04
136
1
W 16
LMV5 QSG Rev 4
Data designation
Fuel volume oil (read only)
(resettable from AZL5... version V4.10)
0...199999999.9 l
0...199999999.9 gal
Number of lockouts
Extra temperature sensor
(from AZL5... version V4.10)
AZL5... ASN
AZL5... parameter set code
AZL5... parameter set version
AZL5... identification date
AZL5... identification number
Burner control ASN
Burner control parameter set code
Burner control parameter set version
Burner control identification date
Burner control identification number
Software version AZL5...
Software version burner control
Software version load controller
Burner identification
Min-output gas
Max-output gas
Min-output oil
Max-output oil
Load limitation enduser (modulating)
Load limitation enduser (multistage)
Temperature limiter switching differential ON
(in address 29: Temperature limiter OFF
threshold, in degrees Celsius / Fahrenheit)
Measuring range temperature sensor
Adaption active / inactive
Adaption state
Start adaption
Adaption output
Permissible values: 40 %, 50 %, 60 %,
70 %, 80 %, 90 %, 100 %
P-value
I-value
Sec 8 Pg 8
Access Data
Data type /
format
coding
R/W*
S32
R
U16
R
U16
°C: *1
°F: *1
R
U8[16]
String
R
U16
R
U16
R
U16[3]
Date
R
U16
R
U8[16]
String
R
U16
R
U16
R
U16[3]
Date
R
U16
R
U16
Hexadecimal
R
U16
Hexadecimal
R
U16
Hexadecimal
R
U8[16]
String
R
U16
PT_LEISTUNG
R
U16
PT_LEISTUNG
R
U16
PT_LEISTUNG
R
U16
PT_LEISTUNG
R/W*
U16
PT_LEISTUNG
R/W*
U16
0: S1
1: S2
2: S3
R
S16
PT_Prozent1
R
U16
0: 150°C / 302°F
1: 400°C / 752°F
2: 850°C / 1562F
R
U16
0: Inactive
1: Active
R
U16
PT_ADAPTION 0...12
R/W
U16
0: Reset value
1: Start
2: Abort
R/W*
U16
PT_Prozent1
R/W*
U16
PT_Prozent01
R/W*
U16
Seconds
www.scccombustion.com
Range
Updating
rate
See "Data
Slow
types" on
page 15
0...65535
Slow
0..2000 °C
Slow
32..3632 °F
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Constant
Upon
reset
0...100 %
Slow
0...100 %
Slow
0...100 %
Slow
1001...1003
0...100 %
Slow
1001...1003
0...100 %
Slow
0...2
Slow
-50...0 %
Slow
0...2
Slow
0...1
Fast
Slow
0...2
Slow
40...100 %
Slow
2...500 %
Slow
0...2000 s
Slow

Advertisement