Figure 5-2 Solar-only network diagram (multiple products connected in parallel)
In the solar-only scenario, the power system works circularly as follows. The power
source preference sequence is solar power > battery.
1.
2.
3.

5.2 Grid Scenario

Figure 5-3 Grid scenario network diagram (one product)
Issue 02 (2021-12-30)
If the solar power is greater than the load power, solar power is supplied to
loads and charges batteries.
If the solar power is less than the load power, solar power and battery power
are supplied to loads at the same time.
If there is no solar power, batteries power loads.